The comparison between FLASC and onshore lithium-ion batteries shows that FLASC becomes increasingly cost-competitive as storage duration increases, ultimately outperforming conventional battery systems for medium- and long-duration applications.
While the unit CAPEX of Li-ion batteries (including cells and enclosures) typically ranges from €200–300/kWh, the installed FLASC system, whose storage medium is simply installed steel pipe, falls within a €210–260/kWh range, already comparable at the component level.
When full project CAPEX is considered, the difference becomes even bigger: the graph shows that offshore Li-ion systems begin above €1100/kWh for short durations and decrease slowly, while even onshore Li-ion remains around €500/kWh at 4 hours and still above €400/kWh at 24 hours. In contrast, FLASC starts near €700-750/kWh (including offshore installation) for short durations but declines rapidly with increasing duration, converging with and eventually dipping below the cost range of onshore Li-ion around the 16–24-hour mark. This cost trend is driven by the fact that FLASC’s energy capacity scales with inexpensive steel pipe rather than battery cells. As duration increases, the marginal cost per kWh becomes significantly lower than that of batteries, which require proportionally more cells and auxiliary systems.
The result is that FLASC delivers similar or lower cost per stored kWh for long-duration storage, while also providing operational advantages such as a 30-year lifetime, no cycling degradation, and reduced safety and environmental risks without use of onshore space.